Search results for "Hearing Tests"
showing 10 items of 11 documents
Postural Sway During Standing and Unexpected Disturbance of Balance in Random Samples of Men of Different Ages
1985
Postural sway behavior while standing and during and after an unexpected disturbance of balance was examined in men aged 31 to 35, 51 to 55, and 71 to 75 years. The groups studied were random samples of men living in the town of Jyväskylä in 1981. Postural sway while standing was more pronounced in the older age groups, whereas after a disturbance of balance postural sway was nearly the same in all age groups. The functioning of the postural control system was correlated with the vibratory threshold on the ankles, grip strength, as well as with aerobic and anaerobic capacity within the age groups. Further, in the youngest age group the functioning of the postural control system was poorer a…
Management of Cochlear Implant Electrode Migration.
2016
The present study reviewed a cochlear implant (CI) patient population after surgery, which received a free-fitting electrode carrier designed for hearing preservation. The aim was to determine the rate of electrode migration of the CI electrodes and present clinical and surgical implications.Retrospective patient review.Tertiary referral university hospital.Two hundred seventy-eight patients implanted uni- or bilaterally with lateral wall electrodes designed for hearing preservation (358 implants). The control group was 323 patients implanted uni- or bilaterally with preformed perimodiolar electrodes (468 implants).Determination of CI electrode migration was conducted according to a clinica…
Single-Sided Deafness: Impact of Cochlear Implantation on Speech Perception in Complex Noise and on Auditory Localization Accuracy.
2017
Objective To assess auditory localization accuracy and speech reception threshold (SRT) in complex noise conditions in adult patients with acquired single-sided deafness, after intervention with a cochlear implant (CI) in the deaf ear. Study design Nonrandomized, open, prospective patient series. Setting Tertiary referral university hospital. Patients Eleven patients with late-onset single-sided deafness (SSD) and normal hearing in the unaffected ear, who received a CI. All patients were experienced CI users. Intervention Unilateral cochlear implantation. Main outcome measures Speech perception was tested in a complex multitalker equivalent noise field consisting of multiple sound sources. …
Evaluation of auditory development in infants and toddlers who received cochlear implants under the age of 24 months with the LittlEARS® Auditory Que…
2010
Abstract Background and Aims Newborn hearing screening and early intervention for congenital hearing loss have created a need for tools assessing the hearing development of very young children. A multidisciplinary evaluation of children's development is now becoming standard in clinical practice, though not many reliable diagnostic instruments exist. For this reason, the LittlEARS ® Auditory Questionnaire (LEAQ) was created to assess the auditory skills of a growing population of infants and toddlers who receive hearing instruments. The LEAQ relies on parent report, which has been shown to be a reliable way of assessing child development. Results with this tool in a group of children who re…
Comparative Study Between Unilateral and Bilateral Cochlear Implantation in Children of 1 and 2 Years of Age
2016
Abstract Introduction The studies that have evaluated the effectiveness of bilateral cochlear implantation in children suggest an improvement in hearing about sound localisation and speech discrimination. In this paper we show the differences in audio-linguistic achievements with early bilateral cochlear implantation versus unilateral, and differences between simultaneous and sequential bilateral implantation. Material and methods We present 88 children with bilateral profound sensorineural hearing loss, treated with bilateral cochlear implantation in 32 cases and unilateral in 56 cases, during the first 12 months (27 children) of life and between 12 and 24 months (61 children). We conducte…
Working Memory Function in Children with Single Side Deafness Using a Bone-Anchored Hearing Implant: A Case-Control Study
2018
The importance of a good hearing function to preserve memory and cognitive abilities has been shown in the adult population, but studies on the pediatric population are currently lacking. This study aims at evaluating the effects of a bone-anchored hearing implant (BAHI) on speech perception, speech processing, and memory abilities in children with single side deafness (SSD). We enrolled <i>n</i> = 25 children with SSD and assessed them prior to BAHI implantation, and at 1-month and 3-month follow-ups after BAHI implantation using tests of perception in silence and perception in phonemic confusion, dictation in silence and noise, and working memory and short-term memory function…
Universal newborn hearing screening in the Italian Region of Sicily in 2018
2021
We have clarified the role of Universal Neonatal Hearing Screening (UNHS) for both early diagnosis and rapid treatment in order to improve the prognosis of the deaf child and reduce patient management costs. Although in Sicily UNHS has been progressively implemented, there is scarce data in the literature on this matter. Therefore, the main objective was to collect in the year 2018 the following data: number of newborns screened for hearing loss, number of infants "referred" to transiently evoked otoacoustic emissions (TEOAE), number of infants with pathologic auditory brainstem response (ABR) and number of infants affected by permanent hearing loss.UNHS monitoring was conducted through the…
Minimal Reporting Standards for Active Middle Ear Hearing Implants.
2017
There is currently no standardized method for reporting audiological, surgical and subjective outcome measures in clinical trials with active middle ear implants (AMEIs). It is often difficult to compare studies due to data incompatibility and to perform meta-analyses across different centres is almost impossible. A committee of ENT and audiological experts from Germany, Austria and Switzerland decided to address this issue by developing new minimal standards for reporting the outcomes of AMEI clinical trials. The consensus presented here aims to provide a recommendation to enable better inter-study comparability.
Newborn hearing-screening project using transient evoked otoacoustic emissions: western sicily experience
2006
Summary Objective To study the incidence of congenital sensorineural hearing loss in all newborns introducing a screen test with a protocol no expensive, with a good “screen sensitivity” that could let an earlier identification of hearing impairment beginning early intervention by 2 months of age and increasing the probability of having language development within the normal range of development. Methods The study was conducted in Sciacca hospital from the beginning of 2003 to our days and was carried out with transient evoked otoacoustic emission using the criteria for PASS or RETEST and considering eventual prenatal and perinatal risk factors. All the newborns were divided into four group…
Optimization of the Speech Test Material in a Group of Hearing Impaired Subjects: A Feasibility Study for Multilingual Digit Triplet Test Development
2021
Background: The development of the global digit-in-noise test requires optimization of each language version on a group of normal-hearing native-speakers. An alternative solution may be an adaptive optimization during ongoing tests in a group of subjects with unknown hearing impairments. The objective of the research was to compare the optimization results between these groups. Methods: Digit triplets consisting of three pseudo-randomly selected digits were presented in speech-shaped noise at various signal-to-noise ratios (SNRs), according to the protocol of the final speech test. Digit-specific and position-specific speech reception thresholds (SRTs) were determined and compared between g…